Captair Flex M391
consommation energetique - 70 W
Ext: 1000 x 630 x 1160/ 1345
Int: 965 x 543 x 866
Ext: 39 3/ 8’ ’ x 24 3/ 4’ ’ x 45 3/ 4’ ’ min 53’ ’ maxi.
Int: 38’ ’ x 21 1/ 2’ ’ x 34’ ’
A ductless fume hood is a safety device used to protect laboratory workers when handling chemicals that pose an inhalation risk.
These fume hoods are equipped with filtration technology that is specific to the type of chemicals handled. These filters capture toxic molecules and particles evaporated in the hood and make it possible to:
Protect users in an effective manner
Reduce the carbon footprint by not releasing any toxic emissions into the atmosphere
Reduce operating costs due to their very low energy consumption
Eliminate all set-up costs related to the installation of a ducted airflow system.
1 - Air intake throught the openings
Air from the laboratory enters the hood through ergonomic openings. The air face velocity creates a dynamic barrier between the user and the chemicals being handled. 2 - Filtration of particles and molecules
The device ventilation system draws the particles and any molecules that have evaporated in the hood toward the filtration system. The level of containment provided by the hood prevents any pollutants from being released into the laboratory.
3 - Clean air into the laboratory
The filtration technology customized to the application traps the molecules that have evaporated within the enclosure. The discharged air is free from all pollutants.
4 - Purification of the ambient air
The continuous recirculation of the filtered air helps to purify the ambient air of the laboratory.
Flex Technology
The configurable design of the filtration column makes the Captair line of ductless fume hoods adaptable to the laboratory safety needs of most applications. The interchangeability of the filters allows the filtration column to be configured specifically for the applications carried out within the hood.
Protection
Containment and filtration in accordance with the AFNOR NF X 15-211 filtration safety standard as recognized by ANSI Z 9.5-2012
Your safety is guaranteed because we adhere to the strict process of evaluating the chemicals that will be used in the hood before approving the application. This assures applicability and provides a true filter life cycle, guaranteeing that the emissions concentration at the filter exhaust will always be lower than 1% of the TLV ( AFNOR NF X 15-211 standard)
Automatic filter saturation alarm
Class 1 product : a maximal safety with a safety filter
Performance and Flexibility
The Flex Filtration Technology covers the major part of laboratory handlings and processes
Select the filter that best suits your application
The BE+ filter offers a high retention capacity of solvents, acids, and bases
Investment and energy savings
No ducting to the building ventilation system is required
Eliminates the energy consumption linked to the air renewal ( air supply/ extraction, filtration, dehumidification, air conditioning)
Very low running energy consumption ranging from 70W to 261W
Erlab' s amazing filtration made easy
No ductwork necessary, your unit is up and running in minutes
Completely mobile and Eeasy to relocate within your lab or to a new building
Energy efficient
No direct emission of pollutants into the atmosphere
We stand by our products with a lifetime warranty